Welcome to visitWuhan Xinshengneng Technology Co., Ltd.
  • Withstand voltage test equipment

  • High voltage test equipment such as transformers and switches

  • Oil and gasification test equipment

  • Relay protection and secondary circuit test equipment

  • Live and online monitoring equipment

  • Electricity inspection power metering equipment

  • Insulation tool test equipment and battery

  • Others

  • High voltage integrated equipment series

  • SF6 gas test equipment series

  • Insulating appliance series

  • Marketing measurement test equipment series

  • Series resonance

    220kV electric integrated CVT adjustable sense series resonance

    Views:

    ●Product introduction

    Product name: 220kV electric integrated CVT adjustable sense series resonance
    Product specifications: XSN (XZ) -80kVA/160kV (electric integrated)
    Applicable test product: Transformer
    The range of tested products: 220kV class transformer CVT, capacitance ≤0.01uF, 110kV class transformer CVT, capacitance ≤0.02uF.

    Product role and function: 1. Help customers to achieve preventive AC withstand voltage test and handover AC withstand voltage test of various tested products;
    2. Test cross-linked rubber-plastic power cables, power transformers, GIS, transformers, insulators, generators, switches and other test products insulation withstand various overvoltage capabilities and AC withstand voltage test for capacitive loads.

    Product nicknames: series resonance withstand voltage test equipment, AC withstand voltage test equipment, resonant booster device for inspection, series resonance withstand voltage tester.

    Test object: 220kV class transformer CVT, capacitance ≤0.01uF, test frequency 50Hz, test voltage 152kV.
    110kV class transformer CVT, capacitance ≤0.02uF, test frequency of 50Hz, test voltage of 76kV.

    ●Technical parameters

    1. Product core parameters:
    Rated capacity: 80kVA;
    Input power: 220V/380V, frequency is 50Hz;
    Rated voltage: 160kV;
    Rated current: 0.5A;
    Working frequency: 50Hz;
    Waveform distortion rate: output voltage waveform distortion rate ≤ 1%;
    Working time: 15 minutes continuous under rated load; 1.1 times of overvoltage for 1 minute;
    Temperature rise: the temperature rise after 15 minutes of continuous operation under rated load is ≤65K;
    Quality factor: the device itself Q≥10 (f=50Hz);
    Measurement accuracy: system effective value 1.5;
    2. Excitation transformer JLB-5kVA/5/10kV/0.2/0.4kV 1 set
    Rated capacity: 5kVA;
    Input voltage: 0-400V, single phase;
    Output voltage: 5/10kV;
    Structure: dry type;
    Weight: about 40kg;
    3. Control box parameters KZX-5kVA/220V/380V 1 unit
    Rated output capacity: 5kVA
    Working power: 220±10%V power frequency
    Output voltage: 0-250V,
    Rated input current: 25A
    Rated output current: 25A
    Running time: 15min continuously under rated capacity
    The maximum temperature of the components under the rated capacity of continuous operation for 15 minutes is ≤65K;
    Noise level: ≤50dB
    Weight: about 15kg;
    4. Adjustable reactor DK-80kVA/160kV 1 section
    Rated capacity: 80kVA;
    Rated voltage: 160kV;
    Rated current: 0.5A;
    Quality factor: Q≥16;
    Rated inductance range: 1100-450H;
    Continuous working time: 15min;
    Adjustable reactor size: Ф480*1550mm;
    Weight: about 280kg/section;

    Back To Top